Photocell (FT2) mode with gate closed

If the photocell is obstructed, the gate cannot open.

The gate opens when an open command is received, even if the photocell is obstructed.

The photocell sends the gate open command when obstructed.
 
Enable close command 6 s after activation of photocell (FT1-FT2)
N.B.: This parameter is not visible if $  or $ is set.

Disabled.

Enabled. When the photocell gate FT1 is crossed, a close command is sent 6 seconds later.

Enabled. When the photocell gate FT2 is crossed, a close command is sent 6 seconds later.

Enable braking at open and closed mechanical stop/limit switch

Disabled.

Enabled. The gate brakes at the end of the manoeuvre against the mechanical open and/or closed
stop.

Enable braking after activation of photocells

Disabled.

Enabled. The gate brakes when the photocells are activated.

Enable braking after STOP command

Disabled.

Enabled. The gate brakes when the control unit receives a STOP command.

Enable braking after open > close / close > open inversion

Disabled.

Enabled. The gate brakes before inverting direction when the control unit receives a close com-
mand while the gate is opening, or an open command while the gate is closing.

Set braking time
WARNING: preferably set low values to ensure that the gate stops correctly.

Settable from 1 to 20 tenths of a second.

Set braking force
CAUTION: +

5 = minimum force ... 8 = maximum force.
 
Select number of motors installed
N.B.: MJXLMWTEVEQIXIVMWQSHMƼIHHMWGSRRIGXJVSQ:%'QEMRWTS[IV[EMXJSVXLIHMWTPE]XS
turn off then reconnect to mains power. 6ITIEXEGUYMWMXMSRTVSGIHYVIWII'LETXIV.

1 motor.

2 motors. IMPORTANT9WIXLIWEQIX]TISJQSXSVJSVFSXLKEXIPIEZIW

Enable limit switches
N.B.: MJXLMWTEVEQIXIVMWQSHMƼIHHMWGSRRIGXJVSQ:%'QEMRWTS[IV[EMXJSVXLIHMWTPE]XS
turn off then reconnect to mains power. 6ITIEXEGUYMWMXMSRTVSGIHYVIWII'LETXIV.
ATTENTIONWIXEZEPYIHMJJIVIRXJVSQ only if the limit switch is connected to the control unit.

No limit switch installed.

Gate open and close limit switches installed.

Gate open limit switches installed.