Photocell (FT2) mode with gate closed
If the photocell is obstructed, the gate cannot open.
The gate opens when an open command is received, even if the photocell is obstructed.
The photocell sends the gate open command when obstructed.
Enable close command 6 s after activation of photocell (FT1-FT2)
N.B.: This parameter is not visible if $ or $ is set.
Disabled.
Enabled. When the photocell gate FT1 is crossed, a close command is sent 6 seconds later.
Enabled. When the photocell gate FT2 is crossed, a close command is sent 6 seconds later.
Enable braking at open and closed mechanical stop/limit switch
Disabled.
Enabled. The gate brakes at the end of the manoeuvre against the mechanical open and/or closed
stop.
Enable braking after activation of photocells
Disabled.
Enabled. The gate brakes when the photocells are activated.
Enable braking after STOP command
Disabled.
Enabled. The gate brakes when the control unit receives a STOP command.
Enable braking after open > close / close > open inversion
Disabled.
Enabled. The gate brakes before inverting direction when the control unit receives a close com-
mand while the gate is opening, or an open command while the gate is closing.
Set braking time
WARNING: preferably set low values to ensure that the gate stops correctly.
Settable from 1 to 20 tenths of a second.
Set braking force
CAUTION: +
5 = minimum force ... 8 = maximum force.
Select number of motors installed
N.B.: MJXLMWTEVEQIXIVMWQSHMƼIHHMWGSRRIGXJVSQ:%'QEMRWTS[IV[EMXJSVXLIHMWTPE]XS
turn off then reconnect to mains power. 6ITIEXEGUYMWMXMSRTVSGIHYVIWII'LETXIV.
1 motor.
2 motors. IMPORTANT9WIXLIWEQIX]TISJQSXSVJSVFSXLKEXIPIEZIW
Enable limit switches
N.B.: MJXLMWTEVEQIXIVMWQSHMƼIHHMWGSRRIGXJVSQ:%'QEMRWTS[IV[EMXJSVXLIHMWTPE]XS
turn off then reconnect to mains power. 6ITIEXEGUYMWMXMSRTVSGIHYVIWII'LETXIV.
ATTENTIONWIXEZEPYIHMJJIVIRXJVSQ only if the limit switch is connected to the control unit.
No limit switch installed.
Gate open and close limit switches installed.
Gate open limit switches installed.