necessary, also checked.
8LI)YVSTIERWXERHEVHW)2ERH)2HIƼRIXLIQMRMQYQWEJIX]
requirements for the operation of automatic doors and gates. In particular, these
standards require the use of force limiting and safety devices (sensing ground
plates, photocell barriers, hold-to-run operation, etc.) intended to detect persons
or objects in the operating area and prevent collisions in all circumstances.
The installer is required to measure impact forces and select on the control unit
the appropriate speed and torque values to ensure that the door or gate remains
[MXLMRXLIPMQMXWHIƼRIHF]XLIWXERHEVHW)2ERH)2
ROGER TECHNOLOGY cannot be held responsible for any damage or injury
caused by the installation of incompatible components which compromise the
safety and correct operation of the device.
If the hold-to-run function is active, the installer will have the obligation to check
the maximum stop distance or the alternative use of the rubber deformable
edge, the closing speed or the gate and in general all aspects indicated by the
ETTPMGEFPIVIKYPEXMSRW1SVISZIVTPIEWIRSXXLEXMJXLIGSQQERHQIERWMWƼ\IH
it must be located in a position guaranteeing the automation system control and
operation and the command type and the use type must comply with the UNI
)2WXERHEVHTVSWTIGXYW[MXLXLIJSPPS[MRKVIWXVMGXMSRWX]TI%SV&
command or type 1 or 2 use).
In case of hold-to-run operation, remove any potential persons away from the
range of action of the automation system's moving parts; the direct commands
must be installed at a minimum height of 1.5 m and must not be accessible to
the public; moreover, unless the device is key operated, they must be located
with a direct view to the motorised part and far from the moving parts.
%TTP]XLIWMKRWMRHMGEXIHF]XLIVIKYPEXMSRWMRJSVGIJSVXLIMHIRXMƼGEXMSRSJXLI
dangerous areas.
Each installed device must have a visible indication of the motorised door or
KEXIMHIRXMƼGEXMSRHEXEMREGGSVHERGI[MXLXLI)2WXERHEVHSV
subsequent revisions
A switch or an omnipolar cut-off switch with a contact opening of at least
3 mm must be installed on the mains power line; put the cut-off switch in
OFF position and disconnect any buffer batteries before performing any cleaning
or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold
and a suitable overcurrent cut-out are installed upstream the electrical installation
in accordance with best practices and in compliance with applicable legislation.
When requested, connect the automation to an effective earthing system that
complies with current safety standards.
The electronic parts must be handled using anti-static conductive wrist straps
with grounding wire.
Only use original spare parts when repairing or replacing products.
The installer must provide the user with complete instruction for using the
motorised door or gate in automatic, manual and emergency modes, and must
hand the operating instructions to the user of the installation upon completion.

Table of Contents

Other manuals for Roger Technology H70/200AC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology H70/200AC and is the answer not in the manual?

Roger Technology H70/200AC Specifications

General IconGeneral
BrandRoger Technology
ModelH70/200AC
CategoryControl Unit
LanguageEnglish

Related product manuals