EN
53
CONTACT DESCRIPTION
30(PED) 31(COM)
Partial open control signal input (N.O.).
On double leaf gate automation systems, by default, the partial opening command
opens LEAF 1 completely.
With single leaf swing gate installations, by default, partial opening is 50% of total
opening.
32(24V~) 33(COM)
Power feed for external devices 24Vac 9 W.
34(SC) 35(COM)
Connection for gate open indicator lamp:HG;WIIƼK
The function of the indicator lamp is determined by parameter $.
34(SC) 35(COM)
Photocell test connectionWIIƼK
The power feed for the photocell transmitters (TX) may be connected to terminal
34(SC).
Set the parameter $ to enable the test function.
Each time a command is received, the control unit switches the photocells off and
on to check that the contact changes state correctly.
36(FT2) 33(COM)
Input (N.C.) for connecting photocells FT2ƼK
The photocells FT2 EVIGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
– . Photocell FT2 is disabled when gate is opening.
– . Photocell FT2 is disabled when gate is closing
– . The gate opens when an open command is received if photocell FT2 is
obstructed.
If the photocells are not installed, jumper the terminals 36(FT2) - 33(COM) or set
the parameters and .
37(FT1) 33(COM)
Input (N.C.) for connecting photocells FT1ƼK
The photocells FT1 EVIGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
– . Photocell FT1 is disabled when gate is opening.
– . Movement is reversed if the photocell is triggered during gate closure.
– . The gate opens when an open command is received if photocell FT1 is
obstructed.
If the photocells are not installed, jumper the terminals 37(FT1) - 33(COM) or set
the parameters and .
38(COS2) 40(COM)
Input (N.C. or 8.2 kOhm) for connecting sensing edge COS2 ƼK.
8LIWIRWMRKIHKIMWGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
– . The sensing edge COS2 is disabled.
If the sensing edge is not installed, jumper the terminals 38(COS2) - 40(COM) or set
the parameter .
39(COS1) 40(COM)
Input (N.C. or 8.2 kOhm) for connecting sensing edge COS1 ƼK
8LIWIRWMRKIHKIMWGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
– . If the sensing edge COS1 is enabled, the gate always reverses.
If the sensing edge is not installed, jumper the terminals 39(COS1) - 40(COM) or set
the parameter .
41(ST) 40(COM)
STOP command input (NC).
The current manoeuvre is arrested if the safety contact opens.
N.B.: the controller is supplied with this contact already jumpered by ROGER TECH-
NOLOGY.
46(ES) 47(COM)
Connection for external power supply for electric lock (potential free contact) 12 Vac
max 15VAƼK
RECEIVER CARD
Connector for plug-in radio receiver board.
8LIGSRXVSPYRMXLEWX[SVEHMSVIQSXIGSRXVSPJYRGXMSRWF]HIJEYPX
– 46WXITQSHIGSQQERHQSHMƼEFPI[MXLTEVEQIXIV).
– 46TEVXMEPSTIRMRKGSQQERHQSHMƼEFPI[MXLTEVEQIXIV).