CONTACT DESCRIPTION
30(PED) 31(COM)
Partial open control signal input (N.O.).
On double leaf gate automation systems, by default, the partial opening command
opens LEAF 1 completely.
With single leaf swing gate installations, by default, partial opening is 50% of total
opening.
32(24V~) 33(COM)
Power feed for external devices 24Vac 9 W.
34(SC) 35(COM)
Connection for gate open indicator lamp:HG;WIIƼK
The function of the indicator lamp is determined by parameter $.
34(SC) 35(COM)
Photocell test connectionWIIƼK
The power feed for the photocell transmitters (TX) may be connected to terminal
34(SC).
Set the parameter $  to enable the test function.
Each time a command is received, the control unit switches the photocells off and
on to check that the contact changes state correctly.
36(FT2) 33(COM)
Input (N.C.) for connecting photocells FT2ƼK
The photocells FT2 EVIGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
 . Photocell FT2 is disabled when gate is opening.
. Photocell FT2 is disabled when gate is closing
 . The gate opens when an open command is received if photocell FT2 is
obstructed.
If the photocells are not installed, jumper the terminals 36(FT2) - 33(COM) or set
the parameters   and  .
37(FT1) 33(COM)
Input (N.C.) for connecting photocells FT1ƼK
The photocells FT1 EVIGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
. Photocell FT1 is disabled when gate is opening.
 . Movement is reversed if the photocell is triggered during gate closure.
 . The gate opens when an open command is received if photocell FT1 is
obstructed.
If the photocells are not installed, jumper the terminals 37(FT1) - 33(COM) or set
the parameters   and  .
38(COS2) 40(COM)
Input (N.C. or 8.2 kOhm) for connecting sensing edge COS2 ƼK.
8LIWIRWMRKIHKIMWGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
. The sensing edge COS2 is disabled.
If the sensing edge is not installed, jumper the terminals 38(COS2) - 40(COM) or set
the parameter  .
39(COS1) 40(COM)
Input (N.C. or 8.2 kOhm) for connecting sensing edge COS1 ƼK
8LIWIRWMRKIHKIMWGSRƼKYVIHF]HIJEYPX[MXLXLIJSPPS[MRKWIXXMRKW
. If the sensing edge COS1 is enabled, the gate always reverses.
If the sensing edge is not installed, jumper the terminals 39(COS1) - 40(COM) or set
the parameter  .
41(ST) 40(COM)
STOP command input (NC).
The current manoeuvre is arrested if the safety contact opens.
N.B.: the controller is supplied with this contact already jumpered by ROGER TECH-
NOLOGY.
46(ES) 47(COM)
Connection for external power supply for electric lock (potential free contact) 12 Vac
max 15VAƼK
RECEIVER CARD
Connector for plug-in radio receiver board.
8LIGSRXVSPYRMXLEWX[SVEHMSVIQSXIGSRXVSPJYRGXMSRWF]HIJEYPX
46WXITQSHIGSQQERHQSHMƼEFPI[MXLTEVEQIXIV).
46TEVXMEPSTIRMRKGSQQERHQSHMƼEFPI[MXLTEVEQIXIV).