R&S ZVL GUI Reference
Channel Menu
Operating Manual 1303.6580.32-06
235
Remote
control:
CALCulate<Ch>:TRANsform:VNETwork:SENDed...
MMEMory:LOAD:VNETworks<Ch>:SENDed:DEEMbedding<Ph_pt>
'<file_name>'
MMEMory:LOAD:VNETworks<Ch>:SENDed:EMBedding<Ph_pt> '<file_name>'
Cal Manager
Opens a dialog to store system error correction and power correction data to the cal pool and to assign
stored correction data to channels.
Cal pool
The cal pool is a collection of correction data sets (cal groups) that the analyzer stores in a common
directory C:\Rohde&Schwarz\NWA\Calibration\Data. Cal groups in the pool can be applied to different
channels and setups. Each cal group is stored in a separate file named <CalGroup_name>.cal. The cal
group name can be changed in the Calibration Manager dialog.
The Calibration Manager dialog contains three main panels:
Calibration State lists all channels and their current calibration state.
Calibration Pool contains a list of all stored correction data sets.
Calibration Properties displays the basic channel settings, the System Error Correction Data, and

Table of Contents