When Dot Drop-out Cannot be Cleared Up
70
Chapter 3 Maintenance
Cleaning of the head surface as an emergency measure
When dot drop-out and/or dot deection is not improved even if cleaning is performed several times,
you can clean the head surface as an emergency measure. Since the head surface (nozzle surface)
is an extremely delicate mechanism, make sure to perform the operation carefully and deliberately.
This operation is an emergency measure. It may damage defect-free parts depending on the symptoms,
worsening the symptoms. If you have any questions, contact your authorized Roland DG Corp. dealer.
Procedure
Perform Step
1.
on P. 62, "Manual Cleaning".
Apply a large amount of cleaning solution to the cleaning stick.
Softly press the cleaning stick to the head surface (nozzle surface).
Press it gently and softly so that the head nozzle is permeated with the cleaning liquid.
Never rub the stick on the surface or press it forcibly.
Perform Steps
3.
and
4.
on P. 65, "Manual Cleaning".