30
RootWave Pro User Guide
If the reset light is off, this may also indicate that the
generator has tripped.
To reset the Treatment Lance after it has been put into Safe Stop
mode, fully release both triggers and press and hold the reset button
until the flashing red light turns off.
Voltage selector switch
Use the power selector switch to select one the following three
settings:
Table 5 Voltage switch settings
Label
Description
Nominal off-load
voltage
L
Low
3,000 V
M
Medium
4,000 V
H
High
5,000 V
You can use different voltage levels and treatment times depending
on the types of weed being treated and ground conditions. When
treating a weed, its stem diameter and height determines the
voltage setting and treatment duration that you should use.
Table 6 Example voltage settings and treatment duration
Weed height before
trimming
1-20 cm
20-80 cm
80-250 cm
Stem diameter
0-1 cm
1-2 cm
>2 cm
Typical voltage setting
Low
Medium
High
Typical treatment
duration
1 second
5 seconds
10 seconds