ENGINE OPERATING
ENGINE START
Before starting the engine, make sure you have completed all necessary tasks for running
the engine:
Fuel tank full.
Battery charged and connected.
Battery voltage over 12 V.
Carburetor Bowden cable is moving freely and carburetor piston connected in idle
position.
For safety reasons, it’s recommended to put the shifting device in "Neutral" (no gear
engaged).
At engine start proceed as follows:
Step
Procedure
1
On a cold engine, pull the choke lever (pos. 1, ) into a vertical position.
Figure 4.1: Choke lever
Step
Procedure
2
Press the power button once, the ignition system is activated (light turns
on). Press the button again until the engine starts. See Fig. “Power button”
NOTE
If the engine does not start, repeat the operation after a few seconds
in the same manner.