OPERATING LIMITS
Operating the engine is only permitted under following conditions:
Recommended coolant temperature rang: 45 °C 85 °C (113 °F 185 °F).
ATTENTION
Operating the engine at a too low temperature could result in piston seizure.
The engine is only allowed to be run at peak performance after reaching the specified
operating temperature.
NOTE
If the engine does not reach the minimum specified operating temperature due to
the low ambient temperature, then the cooling efficiency of the radiator must be
reduced by partially covering the radiator with adhesive tape.
m WARNING
Non-compliance can result in serious injuries or death!
The maximum operating temperature of the engine must not be exceeded. If the tem-
perature is too high, it may result in piston seizure.
NOTE
Dirt must be cleared from the lamination of the radiator at regular intervals to
achieve the best cooling performance.
______________________________________________________
Effectivity: 125 MAX DD2 evo
4
Page 11
Edition: September 01 2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 125 MAX DD2 evo and is the answer not in the manual?

Rotax 125 MAX DD2 evo Specifications

General IconGeneral
BrandRotax
Model125 MAX DD2 evo
CategoryEngine
LanguageEnglish

Related product manuals