CARBURETOR CALIBRATION
The standard carburetor calibration is for an ambient temperature of 25 °C / 77 °F and
400 m / 1310 ft above sea level. At operation with different temperatures and altitudes, the
main jet of the carburetor has to be changed in accordance with Table 1, to optimize en-
gine performance.
NOTE
For engine operation at an ambient temperature below 10 °C / 50 °F, make sure
not to demand full power before the coolant temperature has reached 45 °C /
113 °F.
NOTE
The warranty by BRP-Rotax will no longer apply, if the carburetor calibration is
carried out improperly and causes engine damage.
The following application for smartphones shows the individual setting of your ROTAX®
125 Max DD2 evo engine:
The ROTAX® Max Jetting Guide is an App for Android™ and iOS devices, designed to as-
sist users with setting up the recommended main jet based on the ambient conditions and
the type of engine. The perfect set-up can be calculated in two ways, either automatically
- which requires a GPS signal and an internet connection, or manually - which requires
certain knowledge about altitude and weather conditions.
______________________________________________________
Effectivity: 125 MAX DD2 evo
3
Page 3
Edition: September 01 2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 125 MAX DD2 evo and is the answer not in the manual?

Rotax 125 MAX DD2 evo Specifications

General IconGeneral
BrandRotax
Model125 MAX DD2 evo
CategoryEngine
LanguageEnglish

Related product manuals