FREQUENCY NOTES
ENGINE Before
every
opera-
tion
After
every
opera-
tion
Every
2
hours
of op-
era-
tion
Every
5
hours
of op-
era-
tion
Every
10
hours
of op-
eration
Every
50
hours
of op-
era-
tion
Renew damping material
in after muffler of exhaust
system
X
Check fit and tightness of
exhaust
X
Inspect for oil or water on
the leakage bore at the
crankcase
X
right after every
collision
Verify a tight fit and non
leakage of radiator hoses
and clamps at engine
and radiator
X
right after every
collision
Replace spark plug X as requested
Dirt catching groove on
secondary gear
X
Overload clutch
inspection
X
RAVE X
Clean hoses with com-
pressed air.
4
Page 10
Edition: September 01 2019
Effectivity: 125 MAX DD2 evo