Poultry House Control
36
Precision Mode Programming Steps
settings in ventilation levels. ventilation pressure in Control
Menu | Pressure | Help | Set.
6.11
Install |
System
Parameters
You can access system parameters as
‘Set’ parameters under Help in most
menus. Press the Help key, then
choose the Set option. For experienced
users, all system parameters are
available under this menu.
Some parameters may not
appear under Help | Set if they
do not apply. For example,
they may not apply if there is
no such equipment installed.
Step 2 … 1. Control Menu Comments:
1.1
Control |
Temperature
Curve
1. Enter temperature curves for Heat,
Target and Tunnel entry.
2. Enter temperature curves for
averaged low and high alarm
temperatures.
3. See Management, Alarm Settings
for individual sensor alarm
settings.
See options under Help | Set
such as Non-Brood area
temperature.
Heaters actually turn OFF at
the heat temperature. Happy
Zone for Target and Tunnel is
above their settings.
1.2
Control |
Minimum-
Maximum
Level
Set minimum and maximum levels
based on bird age and the ventilation
level table.
Under Control Mode you can
optionally choose Soft Minimum and
Minimum by Time options.
The Platinum Plus can not go
outside the minimum and
maximum level limits.
For Soft Minimum, see Help |
Set for temperature settings.
1.3
Control |
Humidity
With an Inside Humidity Sensor you
can set up target humidity by bird age.
If humidity is higher than your setting,
the Platinum Plus will increase
ventilation after each ‘Interval’ and
force the higher level for ‘Duration’.
Under Help | Set you can
restrict humidity treatment if
the heaters are on.