Poultry House Control
42
Analog Sensors
The Platinum Plus regards temperature and
humidity sensors as ‘analog sensors’. These sensors
measure a continuous range rather than just on or
off. By default, it comes with 6 sensors which are
connected in standard order.
Digital Sensors
Next are the digital sensors. These monitor
your water consumption and your feed consumption if
your building is equipped. The Feeder Overtime inputs
allow alarming and shutting down your feed system in
the event of bridged feed, an empty tank, or other feed
problem.
Curtain Setup
Curtain Setup tells the Platinum Plus how fast your curtains and side inlets move. It
needs this information to properly calculate automatic inlet advance as well as inlet and
curtain positions. Enter opening and closing
time in seconds for the tunnel inlet curtain
in the Tunnel row, and for the side vents in
the Inlet row.
Analog Sensors
Channel Sensor
1 Temperature Sensor 1
2 Temperature Sensor 2
3 Temperature Sensor 3
4 Temperature Sensor 4
5 Temperature Sensor 5
6 Temperature Sensor 6
7
8
9
10
11
Digital Sensors
Channel Function
1 Water Meter
2 Feeder-1 Overtime
3
4 Feed Count
5
6
7
8
Curtain Setup
Curtain Open Close
1
2
3
4
Tunnel 250 250
Inlet 35 35