Poultry House Control
58
Select Help | Set to turn Advanced
Alarm features on and off.
2.6
Manage | Alarm
Reset
1. Clear Alarm Relay or signaling
for current alarms
2. Restore normal operation after
an emergency pressure situation.
3. Restore normal operation after a
feed overflow situation.
Emergency Pressure and
Feed Overflow result in the
Platinum Plus locking out the
corresponding control
features until you reset with
Alarm Reset. Other
equipment operates normally.
2.7
Manage |
Scale Setting
Enter basic scale parameters for
both bird scales and silos.
‘Mixed’ birds, such as breeders or
pullets are fed according to their
design weights, which are specified
in a growth curve.
Enter curves in the next menu.
Minimum Empty Weight is the
minimum weight reduction to signal
removal of feed.
Feeding stops during silo filling. Set
the threshold change in weight to
trigger filling mode, and resume
time
‘Mixed’ means different
sexes are mixed, but their
data should be separate, or
pullets and males that are
separate but fed according to
predefined weight curves..
‘Sexed’ means unknown sex
including unisex broilers.
Resume time is amount of
time to wait after filling stops
before resuming normal
feeding.
2.8
Manage |
Bird Curve
Enter target bird weights by bird age
for both male and female.
Select the curve in Manage | Scale
Setting menu.
The PlatiNet communication
software can graph actual
versus desired weights on a
personal computer.
2.9
Manage |
Password
Set Owner, up to 5 User and 1
Visitor Password.
Owner can assign passwords, but
not view user passwords.
Users can change data/settings and
their own password.
Visitor can read only.
Hot Key 9 immediately locks
a password protected
controller.
History, Table of Events
records logins.
2.10
Manage |
Emergency
Setting
Enter settings of optional battery
backed emergency cards.
These operate as regular switches
and relays during normal operation.
The battery backed
emergency cards operate in
case of main control failure
under battery backup.
Step 4 … 5. Service Menu Comments:
5.1-5.6
Service |
Calibration
Calibrate Menus. Follow on screen
instructions, or simply enter correct
readings.
Temperature Sensors should
not need cal.