Platinum Plus
59
5.7
Service |
Save to Plug
Save Program Settings to Plug. Large Gold Plug holds up to
8 programs.
5.8
Service | Read
From Plug
Read Saved Program settings from
Plug
Large Gold Plug holds up to
8 programs.
5.9
Service | Modem
Setting
Program a U.S. Robotics Modem
for use at the farm.
5.10
Service | Nipple
Flushing
Set Nipple Flush Times. Select
order under Help | Set.
Step 5 … 4. Test Menu Comments:
4.1
Test | Relays
Check Relay and Switch Operation
4.2
Test | Alarm
Test Alarm Operation
4.3
Test | Analog
Sensors
See machine readings obtained from
analog sensors. Readings are to 1
part in 1000.
4.4
Test | Digital
Sensors
Shorted channels read ‘1’, open
channels read ‘0’.
Channels are polarized. If
paralleling feed monitor and
auger overflow, maintain
polarization.
4.5
Test | Analog
Output
Quickly test light dimmers by
entering specific control voltages.
Select light dimmer channel
in Light Menu | Help | Set.
4.6
Test | Static
Pressure
View machine reading of static
pressure sensor. A zero pressure
reading should be about 130 +/- 25
counts. Zero using trimmer on static
pressure card.
Static Pressure is very low in
poultry barns, about the
amount an insect depresses
the surface of water on a
pond.
4.7
Test | Scales
Test bird scales and silo scales after
calibration.
Limit weight on bird scales to
less than 20 lbs.
4.8
Test |
Communication
Test connections for communication
installations.
4.9
Test | Hardware
Shows plug & play hardware found.