EasyManua.ls Logo

Sakai TW504 - Engine; Engine will Not Start (Starter Motor Does Not Run) 1;3

Default Icon
480 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-092
TROUBLESHOOTING
SW504
4-2. Engine
Check following items before troubleshooting.
No blown fuses and power is applied up to fuses.
Check any ground circuit which belongs to components to be checked.
4-2-1. Engine will not start (Starter motor does not run) 1/3
F-R lever must be in “N”.
Parking brake switch must be applied.
Brake pedal is not depressed.
Reference Fig.: 4-2-1
Check point Check/Cause Action
1. Battery Measure battery voltage or specic gravity.
Standard voltage : 12 V or more
Standard gravity : 1.26 or more
If value is below standard, battery capacity is insufcient.
Charge or replace
battery.
2. Starter Switch Check continuity between O-O according to starter switch
connection table.
Switch is OK if there is continuity between connection
O-O.
If there is no continuity, starter switch is faulty.
Replace starter
switch.
3. Starter Motor (1) When starter switch is ON, measure voltage between
starter motor terminal B and chassis ground.
Standard voltage : 12 V or more
(2) When starter switch is START, measure voltage between
starter motor terminal S and chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and starter motor does not
run, starter motor is faulty.
Replace starter
motor.
4. Starter Relay (1) When starter switch is START, measure voltage between
starter relay terminal 86 inlet wire LY and chassis ground.
Standard voltage : 12 V or more
(2) When starter switch is START, measure voltage between
starter relay terminal 87 inlet wire W and chassis ground.
Standard voltage : 12 V or more
(3) When starter switch is START, measure voltage between
starter relay terminal 30 outlet wire BR and chassis ground
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG, starter
relay is faulty.
Replace starter relay.
5. Battery Relay (1) When starter switch is OFF, measure voltage between
battery relay primary terminal COM and chassis ground.
Standard voltage : 12 V or more
(2) When starter switch is ON, measure voltage between
battery relay coil terminal BR inlet wire LgW and coil
ground terminal outlet wire B.
Standard voltage : 12 V or more
(3) When starter switch is ON, measure voltage between
battery relay secondary terminal NO and chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and item (3) is NG, battery
relay is faulty.
Replace battery relay.

Table of Contents

Related product manuals