A3-2210
Error message :
A
ctuator Sensor Fai
l
Symptom / Cause :
Calibration for density sensor is failed
Troubleshooting method :
1. Check if the driving section of the developer is oper
a
2. Enter the diagnostic mode. Check the TC value.
(Diagnostics > Engine Diagnostics > Engine Test Ro
u
3. If TC value is not proper range. (TC Value : 80~1
2
- Replace the imaging unit.
Replacement part
MLT-R607K : Imaging unit
Service Manual
SCX-8030/8040 series
7-
1
s
hooting
l
ure : #A3-2210. Please open/close door.
a
ted properly.
u
tines > 111-5000 / 5010 / 5020 / 5030)
2
0)