● Code :
A2-1310
A2-1311
A2-1410
A2-1411
● Error message :
Actuator Fan Signal
A2-1510
A2-1511
A2-2310
A2-2311
A2-2810
A2-2811
● Symptom / Cause :
Fan does not operate.
- Fan overheats.
- There is any foreign matter around the fan.
A2-1310 / A2-1311 : SMPS In Fan
A2-1410 / A2-1411 : SMPS Out Fan
A2-1510 / A2-1511 : Duplex Fan
A2-2310 / A2-2311 : FUSER Fan
U3-1310 / U3-1311 : Scan Fan
● Troubleshooting method :
1. Remove the foreign matter around the fan.
2 Turn the machine off and on
.
3. Check the circuit related the fan.
●Replacement part
A2-1410 / A2-1411 : JC31-00129A
A2-1510 / A2-1511 : JC31-00130A
A2-2310 / A2-2311 : JC31-00130A
A2-2810 / A2-2811 : JC31-00130A
U3-1310 / U3-1311 : JC31-00127A
Service Manual
SCX-8030/8040 series
7-
: #A2-1310. Please open/close door.
Failure : #A2-1311. Please open/close door.
: #A2-1410. Please open/close door.
Failure : #A2-1411. Please open/close door.
: #A2-1510. Please open/close door.
Failure : #A2-1511. Please open/close door.
: #A2-2310. Please open/close door.
Failure : #A2-2311. Please open/close door.
: #A2-2810. Please open/close door.
Failure : #A2-2811. Please open/close door.
10. Please open/close door.
Failure : #A2-2911. Please open/close door.
: #U3-1310. Turn off then on.
: #U3-1311. Turn off then on.
SAMSUNG ELECTRONICS
Version 0.05