● Code :
C3-1411
● Error message
● Symptom / Cause :
The data of CRUM is not detected.
1. Imaging Unit is not placed in the set.
2. Physical obstacle is jamming the electronic signal t
3. The signal from set is not proper.
● Troubleshooting method :
1. Open the front cover.
Remove the waste toner container.
2. Is the imaging unit placed in the set or not?
YES! NO! → Place the imaging unit in the set.
↓
Pull out the imaging unit and check the modular ja
Is there any contaminations or obstacles?
YES! NO! → Is the modular jack fixed in proper
↓ YES! NO! → Replace the imaging
↓ ↓
↓ Check whether the electronic signal i
↓
Sweep the contamination or remove the obstacles
Install the imaging unit and do the reverse of No.1.
Is there the error message?
YES! NO! → It’s done.
↓
Check whether the electronic signal is proper or n
● Replacement part
- JC92-02302A : PB
- JC92-02221A : PBA-ENGINE (SCX-8040ND)
Service Manual
SCX-8030/8040 series
7-
stalled. Install the unit.
t. Check the connector and engine board.
SAMSUNG ELECTRONICS
Version 0.05