5-6
MPM-210 Operation Manual
5. MMVER?
Description
Identication query of a module type
Syntax
MMVER?<wsp><module>
Parameters
<module >: 0,1,2,3
Response
<value0>,<value1>,<value2>,<Value3>
value0 : Company (Santec)
value1 : Product code (MPM-211,MPM-212,MPM)
value2 : Firmware Version
Value3 : Board Ver
Example
MMVER? 0
Response : Santec,MPM-211,APP Ver.0000 FPGA
MPM-211Ver.0x2017 0x627, BL 1.02
7. ADDR?
6. ADDR
Description
Check GPIB Address.
Syntax
ADDR?
Response
<value>
Example
ADDR?
Response: 16
Description
Set up GPIB Address
Syntax
ADDR<wsp><value>
Response
<value>: 1 ~ 31
Default
16
Example
ADDR 16
8. GW
Description
Set up Gate way Address.
Syntax
GW<wsp><www.xxx,yyy,zzz>
Parameters
<www.xxx,yyy,zzz>: 0 ~ 255
Default
192.168.1.254
Example
GW 192.168.1.254
9. GW?
Description
Check Gate way Address.
Syntax
GW?
Response
<www.xxx,yyy,zzz>
Example
GW?
Response: 192.168.1.254