EasyManua.ls Logo

Sanyo PLC-HP7000L - Page 49

Sanyo PLC-HP7000L
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-49-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
22 Alpha BB Green 0 - 1000 20 /20/20/20/20/20/ 20/20/20/20/20
23 Alpha BB Blue 0 - 1000 20 /20/20/20/20/20/ 20/20/20/20/20
80 FINE FPGA-Setting
0 UV DLT 0 - 31 3
1 UV Gain 0 - 2047 1030
2 UV SFT 0 - 32767 6180
3 Demo On/Off Dem mode On/Off 1: Display, 0: No display 0 - 1 0
4 Demo Mode Mode 0: Demo0, 1: Demo1 0 - 7 0
5 Area Big Chg Area Id 0 - 4095 67
6 Area Small Chg Area Id 0 - 4095 67
7 Area Chg Sens Area Id 0 - 4095 150
8 Show Mode Test Mode 0: Normal, 1: SHW1, 2:SHW2, 3:Test 0 - 3 0
9 AI_Calc_Mode AI Calcuration 0 - 2 2
230 DATA_SHIFT 0 - 7 4
232 DOT_CKSW 0 - 1 0
81 FINE FPGA-Color Management
0 YRange 0 - 32 8
1 HueRange 0 - 20 10
2 GainRange 0 - 50 30
3 GM_MinSlope Gamma Mini Slope x 100 0 - 10 3
4 GM_MaxSlope Gamma Max Slope x 10 10 - 30 18
5 GM_Converge Gamma Converge x 10 1 - 5 3
6 Not used
7 Not used
8 COLM_GET_KIND_Y_ud No. of Acquire Points 1 - 9 9
9 Not used
10 Not used
11 SameHue 1 - 10 3
12 Cut_UVNorm 0 - 64 5
13 Cur_MinY 0 - 127 0
14 Cur_MaxY 128 - 255 255
15 Same_Y 0 - 63 24
16 Conv_Y 0 - 127 64
17 WB_Limit 0 0 - 255 4
18 WB_Limit 1 0 - 255 40
19 WB_Limit 2 0 - 255 41
20 WB_Limit 3 0 - 255 41
21 WB_Limit 4 0 - 255 41
22 WB_Limit 8 0 - 255 41
23 WB_Limit In 0 - 255 14
24 WB_Limit Out 0 - 255 20
25 WB_Limit PtFlg 0 - 1 1
82 FPGA - Ye Overlay TYPE-L TYPE-R Panel Type
0 DEC_R Ye Overlay Control: R Coefficient(-) 0 - 255 130 170
* The value is initial
-
ized when the panel
type is switched.
1 DEC_G Ye Overlay Control: G Coefcient(-) 0 - 255 30 10
2 B_RATIO Ye Overlay Control: B Coefficient(+) 0 - 255 15 15
3 SAT_SLOPE Ye Overlay Control: Coefficient(Saturation) 0 - 255 71
4 R_SLOPE Ye Overlay Control: Coefficient(R-tint) 0 - 255 16
5 G_SLOPE Ye Overlay Control: Coefficient(G-tint) 0 - 255 16
6 LUM_MAX Ye Overlay Control: Coefficient(Max) PC-Dynamic 0 - 255 255 255
7 LUM_MAX Ye Overlay Control: Coefficient(Max) PC-Standard 0 - 255 255 255
8 LUM_MAX Ye Overlay Control: Coefficient(Max) PC-Real 0 - 255 255 255
9 LUM_MAX Ye Overlay Control: Coefficient(Max) AV-Dynamic 0 - 255 255 255
10 LUM_MAX Ye Overlay Control: Coefficient(Max) AV-Standard 0 - 255 255 255
11 LUM_MAX Ye Overlay Control: Coefficient(Max) AV-Natural 0 - 255 255 255
12 LUM_MAX Ye Overlay Control: Coefficient(Max) AV-Cinema 0 - 255 255 255
13 LUM_MIN Ye Overlay Control: Coefcient(Min) PC-Dynamic 0 - 255 0 0
14 LUM_MIN Ye Overlay Control: Coefcient(Min) PC-Standard 0 - 255 0 0
15 LUM_MIN Ye Overlay Control: Coefcient(Min) PC-Real 0 - 255 0 0
16 LUM_MIN Ye Overlay Control: Coefcient(Min) AV-Dynamic 0 - 255 0 0
17 LUM_MIN Ye Overlay Control: Coefficient(Min) AV-Standard 0 - 255 0 0
18 LUM_MIN Ye Overlay Control: Coefcient(Min) AV-Natural 0 - 255 0 0
19 LUM_MIN Ye Overlay Control: Coefcient(Min) AV-Cinema 0 - 255 0 0
20 YE_SENS Ye Overlay Control: Time Constant 0 - 255 4
21 YE_TESTFLG Ye Overlay Control: Test Flag 0 - 255 3
22 DAC_MAX Not used 0 - 255 255
23 DAC_MIN Not used 0 - 255 0