-87-
Chassis Description
Error Error Code
Error Infomation
(See Powe Failure Detection System)
Error Code
Error Infomation
(See Powe Failure Detection System)
Normal 0 -
Power Failure
1000
AV, AV
1016
MAIN, FAN5
1001
AV, LAN
1017
MAIN, FAN6
1002
MAIN, AD
1018
MAIN, FAN7
1003
MAIN, SI
1019
ERR, PRESSURE
1004
MAIN, F-FPGA
1020
ERR, FIL_DET
1005
MAIN, 5V
1021
ERR, FIL_MTR
1006
MAIN, PIC
1022
ERR, SHUT_MTR
1007
MAIN, 25V
1008
MAIN, KEYSTONE
1009
MAIN, GAMMA
1010
MAIN, 9V
1011
MAIN, S12V
1012
MAIN, FAN1
1013
MAIN, FAN2
1014
MAIN, FAN3
1015
MAIN, FAN4
Temperature Error
2000 Sensor A detects abnormal temperature. (IC1816)
2001 Sensor A fails measurement. (IC1816)
2100 Sensor B detects abnormal temperature. (IC1814)
2101 Sensor B fails measurement. (IC1814)
2102 Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC1692)
2201 Sensor C fails measurement. (IC1692)
2202 Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002 Communication Error on Lamp1
System Error 4000
FPGASW, CONFIG
Shutter Error 5000
SHUTTER, ERROR
Filter Error 6000 Filter clogged
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
✻
<- Latest Error
✻
✻
✻
:
:
✻
How to reset the Error History Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment menu operation".