85
Serial Control Interface
Appendix
This projector provides a function to control and monitor the projector's operations by using the RS-232C serial
port.
Connect a RS-232C serial cross cable to CONTROL
PORT on the projector and serial port on the PC.
(See p.22)
Launch a communication software provided with PC
and setup the communication condition as follows:
1
2
3
Baud rate : 9600 / 19200 bps
Parity check : none
Stop bit : 1
Flow control : none
Data bit : 8
Type the command for controlling the projector and
then enter the "Enter" key.
Example
When you want to change the input to INPUT 2, Type
'C' '0' '6' 'Enter'.
Note:
•EnterwithASCII64-bytecapitalcharactersandone-
bytecharacters.
Note:
•Thedefaultofthebaudrateissetto19200bps.Ifan
erroroccursinthecommunication,changetheserial
portandthecommunicationspeed(baudrate).