EasyManuals Logo

Sartorius Factory Series User Manual

Sartorius Factory Series
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #158 background imageLoading...
Page #158 background image
158
Printing a Data Record
Purpose
You can generate a printout of
weights, other measured values,
identification codes and calibration/
adjustment data for documentation
purposes. You can format the printout
to meet individual requirements.
Available Features
Print manually/automatically:
To print the information contained in
the measured value line (weight
readout, calculated value, numeric
input, alphabetic input)
Line format: You can configure
a data ID code of up to 6 characters
for each of the values printed;
this data ID code is printed at the
beginning of the line
Sample ID: You can configure an
extra line for identification of
each weighed or calculated value
Print application parameters:
You can generate a printout of the
values configured for initialization of
an application before printing the
measured results
ISO/GMP-compliant printout:
To print out parameters relating to
weighing conditions
Auto print: To have a printout
generated automatically when certain
conditions are met, e.g., time
elapsed, stability reached, etc.
Print animal weights: For an
automatic printout of animal weight,
or of animal weight plus calculated
weight after averaging
Auto print checkweighing results: for
automatic printout of a weight when
it lies within preset limits at stability
Auto print with time-controlled
functions: for automatic printout
of weights after a preset time period
has elapsed or at a defined time
Printout of intermediate or final
evaluation for totalizing, formulation
and statistics by pressing the
MR
soft key
Setting a Printout Acceptable
for Legal Metrology
You can configure the scale menu
to generate data records on a
Sartorius printer that are acceptable
for legal metrology (last digit
specially identified):
YDP01IS: [5-5-4]
YDP02: [5-5-5]
YDP03 [5-5-6]
YDP01IS-Label [5-5-7]
YDP02IS [5-5-10]
YDP02IS-Label [5-5-11]
YDP04IS [5-5-14]
YDP04IS-Label [5-5-15]
Factory Settings
Manual/auto print mode:
Individual printout on request,
or automatic printing dependent
on stability:
Manual with stability
[6-1-2]
Print basic application settings:
Printout of one or more initialization
values for the current application: Off
Line format:
ID code for weighed or calculated
value; up to 6 characters:
For other apps/GLP/GMP
(22 characters)
isoCAL function: On without resetting
app
GLP/GMP printout: Automatic
when GLP is selected
ISO/GLP/GMP printout: Off
Auto print:
Automatic printout of
weighed values:
No setting; see: Manual/
auto print mode [6-1-2]
Stop auto print: not possible
[6-2-2]
Time-dependent auto print:
1 display update [6-3-1]
Print animal weights:
Automatic printout of average or
average and calculated values:
Average weight only
Auto print checkweighing:
Automatic printout of weight values
within the checkweighing range
at stability: Off
Auto print time-controlled functions:
Function after time interval: acoustic
signal (not: Automatic printout)
Evaluation of totalizing, formulation
and statistics data:
Evaluation mode, MR function:
Intermediate evaluation, print
§ See Configuring the Scale for
details on how to set parameters

Table of Contents

Other manuals for Sartorius Factory Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Factory Series and is the answer not in the manual?

Sartorius Factory Series Specifications

General IconGeneral
BrandSartorius
ModelFactory Series
CategoryScales
LanguageEnglish

Related product manuals