Configuring the Scale: FC
Configuring the Printout
(Config)
Purpose
You can configure individual printout
formats for each application.
With the formulation, totalizing and
statistics application, you can also
define the values to be printed on
the total printout when the MR key
is pressed.
In the Setup menu you can configure
individual, component or total
data records that contain the items
available for printouts in each
application. Configure these records
after you have configured the
applications, because some entries
in the data record are application-
dependent.
Features
Maximum items in a data record:
60
Individual, component and
total records can be configured
separately
Output individual record:
Press p
Automatic printout of application
data:
Results from animal weighing or
density application (Setup:
Application 1: Density: Printout:
All data)
OK values from checkweighing
application, time-controlled
printouts, 2nd tare memory data
Output component printout:
Totalizing, formulation or statistics
by pressing M+ or M-(Setup:
Application 3: ..., Printout
components: On)
Output total record:
For totalizing, formulation or
statistics by pressing MR
Data records are deleted after
an application or an extra function
is activated or ended in the
application menu
A new pick list is created based
on the currently active application
programs and extra functions
Printout items can be deleted
individually
No printout is generated when the
following settings are configured:
Menu: Print in weighing mode:
automatic
(6 1 4, 6 1 5, 6 1 6)
Application: Printout configuration:
Line format: For raw data
(16 characters)
Form feed:
Select the YDP02 IS- label print
mode (menu code 5 5 11) to
configure automatic form feed to
the beginning of the next label
Additional Functions
§ Save settings and exit printout con-
figuration: Press soft key oo
> Start application
§ Print parameter settings:
When the select bar is on List
or Select: Press p
> Printout (example)
--------
Date/time
SID
Ref. weight
Piece count
Minimum
Nom.no.weighs
etc.

Table of Contents

Other manuals for Sartorius Factory Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Factory Series and is the answer not in the manual?

Sartorius Factory Series Specifications

General IconGeneral
BrandSartorius
ModelFactory Series
CategoryScales
LanguageEnglish

Related product manuals