118
Time-Controlled Functions K
Purpose
With this application program, you
can configure the scale to perform
certain functions (such as automatic
printout of values, store value in
totalization memory) at a given time
or after a set interval.
You can use this application in
combination with any program
chosen from Application 1 (such as
counting, weighing in percent)
and one from Application 3 (such as
totalizing, formulation).
Features
– Time-controlled activation of scale
functions:
– one time only, at a given time
(
Setting= is displayed in
the text line)
– repeatedly, at given intervals
(Interval= is displayed in
the text line before the function is
started, and
Repeat = is displayed after
the function has been started)
– Functions that can be time-
controlled include:
– Acoustic signal (beep)
– Lock in readout
– Automatic printout of values
– Store values for totalizing,
formulation or statistics
– Print time in addition to
weight value
– Store value depending on
the stability parameter
– Tare the scale after printout
of weight values
– Press the corresponding soft key to
cancel time-controlled functions
Factory Settings
Function after time interval:
Automatic printout
of values
Automatic function restart: On
Storage mode:
Without stability
Print then tare: On
Soft Key Functions
Stop Stop the application
Quit Confirm performed
function (e.g., »Lock in
readout« or »Beep«)
Interv Store input interval for
time-controlled functions
Set. Store input time for
one-time performance
of function
Start Start timer function
Printout for Time-Controlled Func-
tions
If the “Automatic printout of values”
parameter is set, the time and weight
(or other value) are printed out.
Time: 10:15:00
N + 150.00 g
Time: Time that the values were stored
N: Net weight