Weigh Cell Operating Instructions 13
Installation
5 Installation
The weigh cells can be supplied in various designs. If
options (special equipment) have been ordered, the
desired options will be added to the cells in the plant.
NOTICE
Once the weigh cells have been removed from the
packaging, they may lose accuracy and the safety of
the device may be impaired if subjected to strong
vibration.
t Do not expose the device to unnecessarily extreme
temperatures, moisture, shocks, blows or vibration.
t It is a good idea to save the box and all parts of the
packaging until you have successfully installed your
equipment. Only the original packaging provides the
best protection for shipment.
5.1 Incoming Inspection
The customer shall inspect the product/service and
packaging immediately upon delivery for proper
functioning, completeness, and absence of defects. This
is to be performed in an incoming inspection within
10 days of delivery of the product or service. The
incoming inspection must take place before installation
into the equipment. Any obvious defects, errors, or
incorrect delivery must be reported in writing. Defects
detected at a later date must be reported in writing
immediately upon detection.
Please consider subsequent commissioning carefully
during the incoming inspection:
— We recommend performing a reproducibility test
using an auxiliary draft shield to make sure there was
no damage to the cells during transport. The YRD01
display unit or the CAS Suite PC configuration
software can be used for assistance.
5.2 Scope of Delivery
Article Quantity
Weigh cell 1
Electronics unit 1
Operating instructions (this document) 1
Power supply unit with country-specific
power cord
1
If necessary, special accessories as listed
on the bill of delivery or in accordance with
any customer-specific agreement
5.3 Unpacking
NOTICE
Additional equipment installed on the load receptor
may impair the function.
The series approval and the specifications achieved for
the entire system are the user’s responsibility.
t Compare the specifications with the information
from the “Technical Data” (see Chapter “13 Technical
Data”, page 50) section.
t The weigh cell must be adjusted after transport.
— WZB...-N, WZB254ND: External adjustment
— WZB...-NC: Internal adjustment
The weigh cell is delivered in antistatic packaging along
with its associated electronics unit.
The other electronic components are packaged
separately on a base plate in an antistatic bag.
Procedure
t Unpack the device.
t Save all parts of the packaging in case they are
needed for shipment. Only the original packaging will
ensure safe transport.