EasyManuals Logo

Satel GSM-X User Manual

Satel GSM-X
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
4 GSM-X SATEL
Dual Path Reporting compliant with EN 50136 (requires GSM-X-ETH module to be
connected).
Converting and retransmitting codes of events received from other devices (simulation of
telephone monitoring station).
Messaging
Notification of events related to the module and received from other devices.
8 telephone numbers to be notified.
Notification by using:
voice messages,
SMS messages,
push messages (provided that GX Control application is installed on the user phone),
CLIP (toll-free).
Programming voice messages from the GX Soft program.
Capability of converting the PAGER type text messages into SMS messages.
Event log
Capability of storing up to 500 events generated by the module or received from
the control panel.
Inputs
4 programmable inputs (NO, NC).
Supervising the state of external devices.
Input blocking capability.
Outputs
4 programmable OC type outputs.
Controlling external devices or signaling troubles.
Control
Control of outputs or blocking of the module inputs by means of:
inputs,
telephone keypad (DTMF),
SMS messages,
GX Soft program,
GX Control application,
CLIP (only outputs control).
Capability of determining the telephone numbers authorized for DTMF, SMS or CLIP
control.
Work in conjunction with INTEGRA / INTEGRA Plus control panels
GSM network as the primary or backup communication path.
Transmitting event codes to the monitoring station via GSM or Ethernet (optionally, after
installation of the GSM-X-ETH module).
Messaging via GSM network.
Remote programming of the control panels from a computer with DLOADX program
installed (quick data transfer via GPRS).

Table of Contents

Other manuals for Satel GSM-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Satel GSM-X and is the answer not in the manual?

Satel GSM-X Specifications

GSM-X

Power IconPower
supply voltage12 V DC ±15%
standby current consumption100 mA
maximum current consumption275 mA
Operating Environment IconOperating Environment
operating temperature range-10 to +55°C
maximum humidity93±3%
environmental classII
Weight and Dimensions IconWeight and Dimensions
electronics board dimensions141 x 70 mm
enclosure dimensions126 x 158 x 46 mm
weight255 g

GSM-X-ETH

Power IconPower
standby current consumption25 mA
maximum current consumption25 mA
Operating Environment IconOperating Environment
operating temperature range-10 to +55°C
maximum humidity93±3%
environmental classII
Weight and Dimensions IconWeight and Dimensions
electronics board dimensions61 x 51 mm
weight25 g

Related product manuals