SATEL GSM-X 51
SMS
SMS function – function run after receiving the control command. The functions are used to
establish communication between the INTEGRA / INTEGRA Plus control panel and the
DLOADX / GUARDX program via the module.
SMS command – control command that can be sent in the SMS message to initiate
communication with the GUARDX / DLOADX program by using the TCP/IP communication
protocol (GPRS or Ethernet). You can enter up to 16 alphanumeric characters except
spaces (digits, letters and special characters).
The content of control commands must vary.
The content of one control command must not be inserted into the content of another
command.
You can include in the SMS message the address of computer the module is to
connect to, and the number of TCP port to be used for communication.
7.17 Remote update
Remote update of the module firmware is made possible by the “UpServ” update server,
which is included in the SATEL product portfolio.
Remote update – if this option is enabled, remote update of the module firmware is possible.
If the option is disabled, the module firmware can only be updated locally (see “Local
update” p. 61). If you select one of the available channels in the “Download update over”
field, the option will be enabled automatically.
Update server – address of the “UpServ” update server. You can enter the IP address or
domain name.
Port – number of the TCP port used for communication with the “UpServ” update server. You
can enter values from 0 to 65535 (0=disabled).
Check for update – you can select how often the module will check for a new firmware
version: Never, Everyday, Once per week or Once per month.
Download update over – you can select the channel that will be used to download updates
from the server:
GPRS – GSM network. The default channel, selected automatically if the “Remote update”
option is enabled.
GSM-X-ETH/GPRS – Ethernet network or GSM network. Ethernet has priority. GSM
network will be used if there is no communication over the Ethernet network.
GSM-X-ETH – Ethernet network.
Selecting the channel will automatically enable the “Remote update” option (if it is
disabled). Communication via the Ethernet network is possible if the GSM-X-ETH module
is installed.
– click to start remote firmware update.
Update server address in SMS – if this option is enabled, you can enter server address and
port number in the SMS message initiating the firmware download from the update server.
If the message contains no address or port number, the module will use the
preprogrammed settings.
Check for update after restart – if this option is enabled, the module will connect to the
update server after each restart and check if a new firmware version is available.