SATEL GSM-X 7
The change of status of the input to which the supervised device is connected may result in:
sending event code to the monitoring station (reporting GPRS / SMS / optionally via
Ethernet network – if GSM-X-ETH module is installed),
notification (messaging) about the event by means of voice message, SMS, push or CLIP.
The inputs can be blocked locally (by means of one of the module inputs, the keypad of
telephone connected to the telephone line output or the GX Soft program) or remotely (by
means of SMS messages, telephone keypad (DTMF), the GX Soft program or the
GX Control application).
The devices connected to the module outputs can be controlled locally (by means of module
inputs, the keypad of telephone connected to the telephone line output or the GX Soft
program) or remotely (by means of SMS messages, telephone keypad (DTMF), CLIP, the
GX Soft program or the GX Control application).
3.3 Simulation of monitoring station
Fig. 3. Module simulating the monitoring station.
The module can forward the event codes received from the control panel to the monitoring
station by means of GSM or Ethernet network (Ethernet optionally, provided the GSM-X-ETH
module is installed). Which reporting path will be used to send the event code depends on
the module configuration.
3.4 Work in conjunction with INTEGRA / INTEGRA Plus control panels
When connected to the INTEGRA / INTEGRA Plus control panel, the module offers the
following benefits:
GSM network as the primary or backup communication path,
transmission of event codes to the monitoring station via GSM or Ethernet network
(Ethernet optionally, provided the GSM-X-ETH module is installed),
messaging via GSM network, including SMS messaging (for the INTEGRA Plus control
panels, an additional feature is available: messaging by means of SMS messages, whose
content corresponds to the description in event log and thus the installer does not need to
define it),