The printing of the type designation on the connection
cable is mandatory.
The product fulls the requirements of
EN 61000-3-11 and is subject to special connection
requirements. This means that use at any freely se-
lectable connection points is not permitted.
Given unfavourable conditions in the power supply
the product can cause the voltage to uctuate tem-
porarily.
The product is intended exclusively for use at con-
nection points which
a) do not exceed a maximum permitted mains im-
pedance “Z
(Zmax = 0.354 Ω (230V)/ 0.330 Ω (400 V)), or
b) have a continuous current carrying capacity of
the mains of at least 100 A per phase.
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Three-phase motor 400 V 3~ / 50 Hz
Mains voltage 400 V 3N~ / 50 Hz
Mains power connection and extension leads must be
5-core = 3~ + N + PE.
Extension cables must have a minimum cross sec-
tion of 1.5 mm² (≤ 25m).
Extension cables must have a minimum cross sec-
tion of 2.5 mm² (> 25m).
AC motor 230V / 50Hz
Mains voltage 230V / 50Hz
Extension cables must have a minimum cross sec-
tion of 1.5 mm² (≤ 25m).
Extension cables must have a minimum cross sec-
tion of 2.5 mm² (> 25m).
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Motor data - type plate
14.2 Transport by crane (Fig 20)
m Attention!
Never lift on the riving knife!
1. Attach the transport straps (not included) on both
sides to the upper bracket (15a) of the guard rail
(15) and to the holder of the transport lever (7).
2. Lift the device up carefully.
15. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customers mains connection as well as the
extension cable used must also comply with these
regulations.
Use a portable safety switch (PRCD) if the residual
current protective circuit (RCD) in the mains power
supply is not provided with a rated residual current
of no more than 30 mA.
The mains power connection is protected with a 16
A slow-blow fuse.
Damaged electrical connection cables
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Pressure points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the wall
outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the designation H07RN-F.

Table of Contents

Other manuals for Scheppach Compact 10t

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach Compact 10t and is the answer not in the manual?

Scheppach Compact 10t Specifications

General IconGeneral
BrandScheppach
ModelCompact 10t
CategoryLog Splitter
LanguageEnglish

Related product manuals