P0-10
Lower limiting
frequency
0.0Hz- Upper limiting Frequency
(P0-09)
0.0 Hz
Yes
40010
P0-11
Jog Frequency
0.0Hz- Upper limiting Frequency
(P0-09)
5.0 Hz
Yes
40011
P0-12
Carrier
frequency
1-16 KHz
5KHz
No
40012
P0-13
Auto storage
of keyboard
frequency in
case of power
down
0: Retention after Power Down
1: No Retention on Power Down
0
No
40013
Fun.
Code
Description
Settings and Range
Default
Value
Basic
Setting
Modifi-
cation
M-bus
Address
17
User Manual
P1- KEYPAD PARAMETERS
P1-00
Default
startup
display
parameter
0: Setting Frequency
1: Output Frequency
2: Output Current
3: Bus Voltage
4: IGBT Temperature
5: Output Voltage
6: Output Power
7: Percentage of Output Current
8: Count Value
9: PI Index Value
10: PI Feedback Value
11: Input Terminal Status
12: Output Terminal Status
13: Power
0
Yes
40100
P1-01
Selection of
display
information
Count From 0 to 13 as given
in P1-00
4
Yes
40101
Fun.
Code
Descrip-
tion
Settings and Range
Default
Value
Basic
Setting
Modifi-
cation
M-bus
Address
P1-02
Password
Disable
0: Enable ; 1: Disable
Yes
401060
P1-03
P1-04
Frequency
Switch
Source
0: Keypad UP/DOWN keys
1: Panel Potentiometer
2: External AI1Current
3: External AI2 Voltage
4: External AI2 POT
5: Communication
0
Yes
40108
P1-05
Reference
Frequency
Lower Limit Frequency (P0-10) to
Upper Limit Frequency (P0-09)
0.0 Hz
Yes
40109
Set Password
0000-9999 0000
Yes
40107