68
User Manual
Display
Protection Functions
Parameters setting, Running status and Fault display
MODBUS RTU over RS485 with a maximum baud
rate of 9600
Over Current, Over Voltage, Under Voltage, Over-
Temperature, Overload, Under Current, System Error
Display parameters
Display Type
HMI with 5 keys, Potentiometer 4 x 7 segment with
4 LED display
Protocol
External
comm.
Operating
conditions
Temperature: -10°C ~ +55°C, Humidity: < 90 %,
No condensation, IP20 Indoor,
<1000 m altitude above sea level
-20°C ~ +60°C
2
<5.9 m/s (0.6 g)
Operating environment
Storage temperature
Vibration
10.3 Product Dimensions

Table of Contents