Using the “Conference Manager” software
102 | ADN Digital Conference System
Loading a configuration
왘 In the menu bar, click “Global Menu” > “Open Conference”.
The “Open” window appears.
If the software is connected to a central unit (see page 100), you can load three
types of configurations:
Loading a configuration ... Actions
... of an active (running) con-
ference (“Active Conference
Document”)
To load your configuration in “Live“
*
operating
mode:
왘 Select the “Open Active Conference Document
from CU” option button.
왘 Click “OK”.
To select the operating mode (“Setup”
**
or
“Live”) in which the configuration is to be loaded:
왘 Select the “Open Conference Document from
CU” option button.
왘 Select the configuration of an active confer-
ence (marked with an asterisk “*”) from the
drop-down list.
왘 Select the operating mode (“Setup” or
“Live”) and click “OK”.
* After loading a configuration, the conference automatically starts in “Live” operating
mode. Also observe the information on page 103.
** In “Setup” operating mode, you can adapt existing configurations to your needs.
... of a non-active conference
(“Conference Document”)
To select the operating mode (“Setup” or “Live”)
in which the configuration is to be loaded:
왘 Select the “Open Conference Document from
CU” option button.
왘 Select the configuration of a non-active con-
ference (not marked with an asterisk “*”)
from the drop-down list).
왘 Select the operating mode (“Setup” or
“Live”) and click “OK”.
... of a conference saved locally
on the hard disk (“Open Local
Conference Document”)
***
*** Only available if you are using the Windows version of the software – even if there is no
connection to a central unit
왘 Select the “Open Local Conference Document”
option button.
왘 Click “OK” and select the desired configura-
tion from the “Open Conference” file selection
dialog box (file extension “*.adn”).
왘 Click “OK”.
The conference is loaded in “Setup” operating
mode.
If you open a configuration in “Setup” operating mode, the password set
will be prompted (where applies) (see page 98).