ADN Digital Conference System | 129
Using the “Conference Manager” software
This setting affects your conference as follows (example):
To determine the behavior when the individual speaking time is exceeded:
Tick/untick the “Switch off Microphone on Talktime Exceed” check box.
Setting the function of the
“All Micros OFF“ button
The “Clear Request List on Cancel” check box allows you to set the function of the
All Micros OFF” button (see page 139).
Tick/untick the “Clear Request List on Cancel” check box in the “Conference
Settings” window.
Locking/unlocking the central unit’s
operating menu
To protect the central unit’s operating menu against any accidental change of
settings:
In the “Conference Settings” window, select the “Locked” option button behind
CU Lock Status”.
The central unit’s operating menu is locked. To adjust settings via the operating
menu, you have to deactivate the lock mode (see page 44).
To deactivate the lock mode:
Select the “Unlocked” option button behind “CU Lock Status”.
The central unit’s operating menu is unlocked.
“Talk Time Limit”
(speaking time limit)
15 (minutes)
“Premonition Time Limit”
(advance warning time)
60 (seconds)
Effect 60 seconds before the speaking time limit expires,
i.e. after 14 minutes in this example, the signal light
ring and the microphone LED start flashing
red.
Check box Behavior of the conference unit when the individual
speaking time is exceeded
is ticked The individual speaking time is terminated.
The signal light ring and the microphone LED
go off.
is unticked The individual speaking time is continued.
The signal light ring and the microphone LED
flash red until the speaker has finished speaking.
Check box Function of the “All Micros OFF” button
is ticked Deactivates all delegate units and clears a request-to-
speak list (if available).
is unticked Deactivates all currently active delegate units.
All requests to speak are retained.