ADN Digital Conference System | 145
Using the “Conference Manager” software
“Error“
High Current status:
(Port1=ALERT/OK,
Port2=ALERT/OK)
[CU Main
######]/
[PS ######]
Current at PORT I/PORT II of the
central unit/power supply is
within the permissible range
(“ok”)/too high (“ALERT”)
Low Voltage Alert at Unit
Pos.###
[Unit at
Pos.###]
Voltage required for powering
the conference units is too low
Microphone Limit changed
to ## due to number of
chairperson units
[CU Main
######]
Microphone limit has been
changed due to changed
number of chairperson units
Microphone limit read-
justed to max possible
value=##
[CU Main
######]
Microphone limit has been
adjusted to the maximum pos-
sible value.
Premonition Time read-
justed to ##s due to Talk
Time Limit conflict
[CU Main
######]
Advance warning time has been
adjusted due to conflicts with
the speaking time limit
Short-Circuit status:
(Port1=ALERT/OK,
Port2=ALERT/OK)
[CU Main
######]/
[PS ######]
Short-circuit at PORT I/PORT II of
the central unit/power supply
(“ALERT”)/no short-circuit at
PORT I/PORT II of the central
unit/power supply(“ok”)
Column “Description“ “Location“ Meaning
Column “Description“ “Location“ Meaning
Cabling error on power
supply unit at pos.###
(Port##.##)
[CU Main
######]
Faulty system cable connected
to power supply
Conference Unit S/N:
###### failure at
Pos.###: Please contact
service
[CU Main
######]
Defective conference unit
has been detected. Contact
your Sennheiser partner
(see page 153).
Corrupted USB device [CU Main
######]
Error of the USB mass storage
device
CU recording performance
problem
[CU Main
######]
Performance problem of the
CU1. In case of repeated occur-
rence, contact your Sennheiser
partner (see page 153.
Insufficient USB device
performance
[CU Main
######]
Read/write speed of the USB
mass storage device is not
sufficient
Invalid USB device format [CU Main
######]
USB mass storage device
uses a file system that is
not supported
No USB device available [CU Main
######]
No USB mass storage device
available
Selftest result: Error [CU Main
######]
Self-test has failed
Set Conference mode=##
denied => Value out of
range {Automatic=##,
Overrun=##, Request=##,
Push_To_Talk=##}
[CU Main
######]
Conference mode could not be
changed (“denied”) because
the value is out of the
permissible range