ADN Digital Conference System | 53
Configuring the conference system via the central unit
The speaking time limit becomes effective only if it is activated in the “Talk Time
Status” menu item (see previous section).
Please note that the speaking time limit applies to each and every input to the
discussion.
Setting the advance warning time – “Premonition Time Limit”
Adjustment range: “00” ... “120”, adjustable in steps of 10 seconds
Set the advance warning time.
This setting affects your conference as follows (example):
Determining the behavior when the individual speaking time is exceeded –
“Reaction on Talktime Exceed”
Determining the behavior when the individual speaking time is exceeded –
“Reaction on Talktime Exceed”
Select and call up the
“Conference” submenu
Select and call up the
“Premonition Time
Limit” menu item
Select the desired
setting; store the
setting
Main Menu
Conference
Audio
System
Conference
Talk Time Status
Talk Time Limit
Premonition Time Limit
Premonition Time Limit
Conf. Mode
Seconds 20
20 Sec 20 Sec
“Talk Time Limit”
(speaking time limit)
15 (minutes)
“Premonition Time Limit”
(advance warning time)
60 (seconds)
Effect 60 seconds before the speaking time limit
expires, i.e. after 14 minutes in this example, the
signal light ring and the microphone LED
start flashing red.
Select and call up the
“Conference” submenu
Select and call up the
“Reaction on Talktime
Exceed” menu item
Select the desired
setting; store the
setting
Main Menu
Conference
Audio
System
Conference
Talk Time Limit
Premonition Time Limit
Reaction on Talktime Exceed
Reaction on Talktime Exceed
Continue
Cancel
Continue Continue
Event The end of the individual speaking time is reached.
Behavior Continue”:
The individual speaking time is continued. The signal light ring
and the microphone LED flash red until the speaker has finished
speaking.
Cancel”:
The individual speaking time is terminated. The signal light ring
and the microphone LED go off.