Manual – Fieldbus Interface DFE24B EtherCA
6
Parameterization return codes
Operating Behavior on EtherCAT
®
6.4 Parameterization return codes
6.4.1 Elements
In the event of an incorrect parameterization, the inverter sends back various return
codes to the parameterized master. These codes provide detailed information about the
cause for the error. Generally, these return codes are structured according to the follow-
ing elements.
Error class
Error code
Additional code
6.4.2 Error class
The error class element (1 byte) provides a more exact classification of the error type.
6.4.3 Error code
The error code element (1 Byte) allows for a more detailed identification of the error
cause within the error class. For Error class 8 = Other error, only Error code = 0 (Other
error code) is defined. In this case, detailed identification is made using the additional
code.
6.4.4 Additional code
The additional code (2 bytes) includes the detailed error description.
Class (hex) Designation Meaning
1 vfd state Status error of the virtual field device
2 application reference Error in application program
3 definition Definition error
4 resource Resource error
5 service Error during execution of service
6 access Access error
7 ov Error in the object list
8 other Other error