AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 32
a. Left lower cabinet unit
1) Open the left lower cabinet.
2) Remove the resin E-ring, and remove the pressure fulcrum shaft.
3) Remove the left vertical transport PG stopper plate.
4) Open the left door, and remove the left lower cabinet unit.
b. Left vertical transport unit
1) Remove the left lower cabinet unit. (See a. Left lower cabinet
unit)
2) Remove the left vertical transport PG stopper plate.
3) Open the left vertical transport unit, and remove it.
c. Paper feed tray 1 and 2 left PG unit
1) Remove the left lower cabinet. (See a. Left lower cabinet unit)
2) Remove the left vertical transport unit. (See b. Left vertical trans-
port unit)
3) Remove the paper feed tray 1 and 2 left PG unit.
c-1. Transport roller 11 (Drive)
1) Remove the paper feed tray 1 and 2 left PG unit. (See c. Paper
feed tray 1 and 2 left PG unit)
2) Remove the E-ring, the drive collar, and the one-way gear.
Be careful of the installing direction.
3) Remove the E-ring and the bearing, and remove the transport
roller 11 (Drive).