Operating Instructions Chapter 1
C4000 Standard/Advanced
8009861/WA65/2012-06-12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 9
Subject to change without notice
About this document
Software notes show the location in the CDS (Configuration & Diagnostic Software) where
y
ou can make the appropriate settings and adjustments. Go to the menu View, Dialog box
of the CDS and activate the item File cards to view the named dialog fields as required.
Alternatively, the Software Assistant will guide you through the appropriate setting.
If you use the SICK switching amplifier UE402, you will find the functions under the same
names, however to some extent in different places in the CDS Configuration dialog box.
This is dependent on the scope of the related function. The operating instructions for the
UE402 contain detailed information.
Sender and receiver
In drawings and diagrams, the symbol denotes the sender and the symbol denotes
the receiver.
The term “dangerous state
The dangerous state (standard term) of the machine is always shown in the drawings and
diagrams of this document as the movement of a machine part. In practical operation,
there may be a number of different dangerous states:
machine movements
electrical conductors
visible or invisible radiation
a combination of several risks and hazards

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Standard and is the answer not in the manual?

SICK C4000 Standard Specifications

General IconGeneral
TypeSafety Light Curtain
Number of BeamsVaries with protective field height and resolution
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65, IP67
Type IECType 4
CategoryCategory 4
Protective Field Height300 mm to 1800 mm
Supply Voltage24 V DC
ConnectionM12 connector
OutputsPNP
Resolution14 mm, 30 mm
Operating Temperature-25 °C ... +55 °C