2 Safety information
2.1 Intended use
The device is an intelligent, opto-electronic ID sensor and is used for automatic, fixed
identification and decoding of bar codes on moving or stationary objects.
The device transmits the data content of the decoded bar codes to a higher-level
control (PLC) for coordinating further processing.
The device is primarily designed for use in industrial and logistics areas. The device
meets the applicable requirements for industrial robustness, interfaces and data proc‐
essing.
NOTE
The bar codes being read must conform to at least quality level C in accordance with
ISO/IEC 15416.
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies to use of the product that does not conform to
its intended purpose and is not described in this documentation.
2.1.1 Operating restrictions
NOTE
Radio interference may occur when the device is used in residential areas!
■
Only use the device in industrial environments (EN 61000-6-4).
2.1.2 Conditions for specified enclosure rating
To ensure compliance with the IP65 enclosure rating of the device and connecting
cable during operation, the following requirements must be met: If these requirements
are not met, the device does not fulfill any specified enclosure rating.
•
The head of the connecting cable (D-Sub male connector) is firmly screwed to the
contacted female connector.
•
If an extension cable is used, a corresponding rubber seal (SICK accessory) must
be fitted between the two D-Sub plug connectors. The plug connectors must
be screwed together tightly. You can find a suitable IP65 rubber seal online at:
www.sick.com/CLV61x.
For further warranty provisions, see the General Terms and Conditions of SICK AG, e.g.
on the delivery note of the device.
2.2 Improper use
Any use that goes beyond the areas specified below is considered improper use. This
applies to use outside the technical specifications and the specifications for intended
use.
•
The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.
•
The device must not be used in explosion-hazardous or corrosive areas or under
extreme ambient conditions.
•
The device must not be operated in the ambient temperature range below 0 °C.
•
The use of accessories not approved by SICK AG is at your own risk.
2 SAFETY INFORMATION
8
O P E R A T I N G I N S T R U C T I O N S | CLV61x 8017840/19OF/2021-10-28 | SICK
Subject to change without notice