Minimum Typical Maximum
Input voltage HIGH (active) 13 V 24 V 30 V
Input current HIGH 2 mA 5 mA 7 mA
Input voltage LOW (deactivated) –3 V 0 V 3 V
Input current LOW –0.1 mA 0 mA 0.5 mA
Control switch actuation time 50 ms
Permissible cable resistance
1)
Supply cable
2)
2.5 Ω
Cable between host and guest 1 Ω
1)
Limit the individual conductor resistance to the specified values to ensure that the light curtain functions
correctly. (Also observe IEC 60204-1.)
The specified values apply to the total resistance of each wire including contact and connector resis‐
tances.
2)
If a T distributor is used, the specified values apply to the resistance of the entire cable from the system
connec
tion of the device to the connection in the control cabinet.
For a cascade, the specified values apply to the resistance of the entire cable from the system connec‐
tion of the last guest device to the connection in the control cabinet.
Table 44: Technical data for receiver
Minimum Typical Maximum
Output signal switching devices
(OS
SDs)
2 PNP semiconductors, short-circuit protected
1)
, cross-
circuit monitored
Response time "Response time", page 131
Duration of OFF state 100 ms
Switch-on delay 3 × response
t
ime
ON state, switching voltage HIGH
(U
r
ms
)
2)
U
V
– 2.25 V 24 V U
V
OFF state, switching voltage LOW
2)
3)
0 V 0 V 2.0 V
Current-carrying capacity of the
O
SSDs
500 mA each
Leakage current of the OSSDs 2 mA each
Load capacity 2.2 µF
Load inductance 2.2 H
Test pulse data
4)
Test pulse width 150 µs 300 µs
Test pulse rate 3 s
-1
5 s
-1
10 s
-1
Discrepancy time (time offset
be
tween switching of OSSD2 and
OSSD1)
1 ms
Inputs
Input voltage HIGH (active)
2)
11 V 24 V 30 V
Input current HIGH 6 mA 10 mA 20 mA
Input voltage LOW (deactivated)
2)
–3 V 0 V 5 V
Input current LOW –2.5 mA 0 mA 0.5 mA
external device monitoring input (EDM)
Connected contactors
Permissible dropout time 300 ms
Permissible pull in time 300 ms
TECHNICAL DATA 13
8023872/18YZ/2021-01-14 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD
129
Subject to change without notice