Minimum Typical Maximum
Reset pushbutton input (RES)
Control switch actuation time 50 ms
Muting signal 1 and muting signal 2 inputs (In1, In2, In4)
Input filter 50 ms
Muting sensors
Output type PNP switching
Current consumption of a muting
sensor
50 mA
Supply voltage U
v
– 1 V U
v
Application diagnostic output (ADO)
PNP semiconductor, short-circuit protected
1)
Output voltage HIGH (active) U
V
– 3 V
Output voltage LOW (deactivated) High resistance
Output current HIGH (active) 100 mA
Permissible cable resistance
5)
Supply cable
6)
7)
1 Ω
8)
Cable between host and guest 1 Ω
Cable between OSSD and load 2.5 Ω
All additional wires at the system
c
onnection and extension connection
6)
2.5 Ω
1)
Applies to the voltage range between -30 V and +30 V.
2)
According to IEC 61131-2.
3)
The specified values are the switching voltage supplied by the safety light curtain. If higher voltages are
impressed externally, the maximum value of 2.0 V can be exceeded.
4)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test pulses do not result in deactivation when using the above parameters.
5)
Limit the individual conductor resistance to the specified values to ensure that the light curtain func‐
tions correctly, particularly that a cross-circuit between the outputs is safely detected. (Also observe
IEC 60204-1.)
The specified values apply to the total resistance of each wire including contact and connector resis‐
tances.
6)
If a T distributor is used, the specified values apply to the resistance of the entire cable from the system
connection of the device to the connection in the control cabinet.
For a cascade, the specified values apply to the resistance of the entire cable from the system connec‐
tion of the last guest device to the connection in the control cabinet.
7)
The supply cable must not be used to connect other loads with the exception of the senders.
8)
If a T distributor is used and the input current is greater than 1.2 A, the conductor resistance must not
exceed 0.5 Ω.
If the device is not used in a cascade, a T-connector is not used, and no inductive OSSD loads (e.g.,
contactors) are applied, the conductor resistance must not exceed 2 Ω.
Table 45: Operating data
Minimum Typical Maximum
System connection
1)
Male connector, M12, 5-pin
Male c
onnector, M12, 8-pin
Extension connection Optional, female connector, M12, 5-pin
Lengths of cable for connecting
c
ables and in cascades
"Length of cable", page 132
Lengths of cable for other cables on
the extension connection
10 m
Ambient operating temperature
2)
3)
4)
0 °C +55 °C
Air humidity (non-condensing) 15% 95%
13 TECHNICAL DATA
130
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK
Subject to change without notice