Symbology Reading Control
Operating Instructions
IDM corded & IDM Bluetooth
46
© SICK AG · Germany · All rights reserved · Subject to change without notice
8017159/2014-04-24
3.7.4 Code 39/ Code 32
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Code 39 Family Setting
SS Disable Code 39 0
SS Enable Code 39 1
SS Select Standard Code 39 as primary format 2
SS Select Full ASCII Code 39 as primary format 3
SS Select Code 32 (PARAF, Italian Pharmaceutical) as
primary format
4
SS Disable start/stop symbol transmission 5
SS Enable start/stop symbol transmission 6
SS Disable Code 32 leading A transmission 7
SS Enable Code 32 leading A transmission 8
SS Disable MOD 43 check digit verification 9
SS Enable MOD 43 check digit verification A
SS Disable check digit transmission B
SS Enable check digit transmission C
SS Disable Code 39 buffering D
SS Enable Code 39 buffering E
Trioptic Code 39 Setting
SS Disable Trioptic Code 39 0
SS Enable Trioptic Code 39
1
Code 39 Min. Length
SS Default (01) FIN
MS 01-98 (2 digits)
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
Code 39 Max. Length
SS Default (98) FIN
MS 01-98 (2 digits)
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

Table of Contents

Other manuals for SICK IDM1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM1 Series and is the answer not in the manual?

SICK IDM1 Series Specifications

General IconGeneral
BrandSICK
ModelIDM1 Series
CategoryScanner
LanguageEnglish

Related product manuals