3.10.2 Sleep Time-out, Power Off Time-out
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Sleep Time-out of
connected state
SS 6 (x5) minutes FIN
MS 0-99 (x5) minutes (2 digits)
If you don’t want the scanner to enter sleep mode, please
set time-out to “0”.
Sleep Time-out of
disconnected state
SS 1 minute FIN
MS 0-99 minutes (2 digits)
If you don’t want the scanner to enter sleep mode, please
set time-out to “0”.
Power Off Time-Out
SS 6 (x5) minutes FIN
MS 0-12 minutes (2 digits)
If you don’t want the scanner to enter power off mode,
please set time-out to “0”.
Sleep Time-out control
The sleep time-out control can be set under radio connection or disconnection state. If the scanner is not
used within the preset time-out duration, it will automatically enter “Sleep Mode” for power saving purpose.
You can disable this function by setting the time-out duration to “0”.
Power off Time-out control
When the scanner is under sleep mode, it is preset to enter “Power Off” automatically if it is not woken up
after time-out duration. If you would like to wake up the scanner press the trigger button. Meanwhile you can
disable this function by setting the time-out duration to “0”.

Table of Contents

Other manuals for SICK IDM1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM1 Series and is the answer not in the manual?

SICK IDM1 Series Specifications

General IconGeneral
BrandSICK
ModelIDM1 Series
CategoryScanner
LanguageEnglish

Related product manuals