3.10 Bluetooth Operation Control (IDM Bluetooth series)
3.10.1 Out-of-range Scanning, Link Supervision Time-Out, Beeping Control
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Out-of-range Scanning
SS Disable 0
SS Enable
1
Link Supervision Time-out
SS 1 sec 0
SS 3 secs 1
SS 5 secs 2
SS 7 secs 3
SS 9 secs 4
Only available in PAIR & PICO mode
Beeping Control
SS Radio connected/ disconnected Beep On 0
SS Radio connected/ disconnected Beep Off 1
SS Battery Power Low Beep On 2
SS Battery Power Low Beep Off 3
Out-of-range Scanning
When radio link is built between the scanner and remote host device, the scanner will transmit each scanned
data right after scanning the barcode data. The scanner is preset to not scan any barcode data when it loses
the radio connection. You can enable the Out-of-range Scanning function to continue scanning barcode data
into the internal memory buffer until radio link resumed.
Link Supervision Time-out
This is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status
every preset seconds.

Table of Contents

Other manuals for SICK IDM1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM1 Series and is the answer not in the manual?

SICK IDM1 Series Specifications

General IconGeneral
BrandSICK
ModelIDM1 Series
CategoryScanner
LanguageEnglish

Related product manuals