EasyManua.ls Logo

SICK PROFINET DL100 Pro - Page 71

SICK PROFINET DL100 Pro
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 31: MF2 module parameters
Name Description
Function MF2 Select function for MF2 output.
Options
[Output] Distance Threshold: Output is switched when the distance has
been overwritten from the module parameter [MF2 Distance] threshold.
[Output] Speed Threshold: Output switches when the speed limit from
the [MF2 Speed] Threshold module parameter has been exceeded. The
direction is set in the [MF2 Speed] Mode module parameter.
[Output] Service: The output switches if at least one of the service bits
selected under [MF2 Service] Laser Warning...[MF2 Service] Heating has
been set.
Factory setting
[Output] Distance Threshold
[MF2] Active State Select the active level or signal edge of the MF2.
Options
low
High
Factory setting
low
[MF2 Distance] Thresh‐
old [mm]
Enter the distance threshold value.
Options
-300,000 ... 300,000 [mm]
Factory setting
1,990 [mm]
[MF2 Distance] Hyste‐
resis [mm]
Enter the distance threshold hysteresis.
Options
1 ... 300,000 [mm]
Factory setting
10 [mm]
[MF2 Speed] Threshold
[mm/s]
Enter speed threshold. The switching hysteresis is fixed at 100 mm/s.
Options
0 ... 15,000 [mm/s]
Factory setting
5,000 [mm/s]
[MF2 Speed] Mode Select direction for detecting the speed overrun.
Options
negative direction [-]
positive direction [+]
both directions [+/-]
Factory setting
both directions [+/-]
[MF2 Service] Laser
Warning
The output switches when the aging of the laser diode means that the
device is nearly due to be replaced.
Options
off
on
Factory setting
on
PROFINET IO INTERFACE 10
8015069/19H9/2021-10-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFINET
71
Subject to change without notice

Table of Contents

Related product manuals