Table 5: AC/DC relay
Relay
3
WT24-2R2x0
H
I
max.
= 4A @ 250V AC
4A @ 24V DC
0.125A @ 250 V DC
UL: 4A @ 250 V AC, general
use
4A @ 250 V AC, resistive
(NO)
3A @ 250 V AC, resistive
(NC)
4A @ 24 V DC, NO, general
use
3A @ 24 V DC, NC, general
use
R300
B300 (NO contacts only)
D
WT24-2R5x8, WT24-2R5x9: I
max.
= 2.5A @ 250 V AC, 2.5A @ 24 V DC, 0.125A @ 250 V
DC
7 Additional functions
Alarm
Alarm output: the sensor (WT24-2Vxxx) features a pre-failure notification output
(“Alarm” in connection diagram [see "WT24-2Bxxx, WT24-2Vxxx", page 7]), which issues
a notification if the sensor is only ready for operation to a limited extent. The LED indi‐
cator flashes in this case. Possible causes: sensor is contaminated, sensor is out of
alignment. In the good state: LOW (0), if excessively contaminated HIGH (1).
Table 6: Alarm
Alarm (≤ 100 mA)
ADDITIONAL FUNCTIONS 7
8008784.14BT | SICK
Subject to change without notice