8.1.3 Requirements and Standards
The following parameters are achieved according to the safety case:
according to DIN EN ISO 13849-1:2008-12
MTTFd: >100 years
DC = 99%
Category 4
Performance Level e
according to EN 61508-1:2010 and EN 61800-5-2:2014-06
PFH = 0
SFF = 100 % (if there are PFH values, then SFF<100%)
HFT = 0
The safety concept K2 meets the requirements of SIL 3 according to the standards
named above.
Requirements according to DIN EN 61800-5-2:2014-06
When connected appropriately, the safety concept K2 does not supply any share of dan-
gerous, undetected errors in the safety chain for the function STO.
Thus the stop function 0+1 according to DIN EN 60204-1 is realized.