IDs in ACCU-1-LL
In ACCU-1-LL, the system program stores IDs about the processing
result, with which the cause of a warning or error is specified in more
detail.
Bit no. 7 6 5 0
W E Cause of error/warning
The following group bits are fixed:
Bit no. 7 (W) = 1: warning
Bit no. 6 (E) = 1: error
ID Meaning
01H Function was correctly processed
45H
47H
4DH
Error:
Block type not permitted
Block does not exist
Online function COMPRESS MEMORY active
8DH
8EH
Warning:
Conflict with an online function (except for
"compress memory")
10 ms waiting time not elapsed
Example
Table 6-5 Result IDs of OB 124 in ACCU-1-LL
:L KY 6,100 This sequence of operations deletes
:JU OB 124 data block DX 100 in the user
: memory
OB 124: Delete STEP 5 Blocks
CPU 948 Programming Guide
6 - 16 C79000-G8576-C848-04