Note
If you change the order or the number of formal operands in the
formal operand list, you must also update all STEP 5 statements
in the function block that reference a formal operand and also
the block parameter list in the calling block!
Program or change function blocks only on diskette or hard disk
and then transfer them to your CPU!
Formal operands
The following parameter and data types are permitted as the formal
operands of a function block (also known as block parameters):
Parameter type Data type
I = input parameter
Q = output parameter
BI/BY/W/D
D = data KM/KH/KY/KS/KF/
KT/KC/KG
B = block operation
T = timer
C = counter
none
(no type can be specified)
I, D, B, T or C are parameters that are indicated to the left of the
function symbol in graphic representation.
Parameters labelled with Q are indicated on the right of the function
symbol.
The data type indicates whether you are working with bits, bytes,
words or double words for I and Q parameters and which data format
applies to D parameters (e.g. bit pattern or hexadecimal pattern).
Table 2-5 Permitted formal operands for function blocks
Function Blocks
CPU 948 Programming Guide
C79000-G8576-C848-04
2 - 27

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 948 and is the answer not in the manual?

Siemens CPU 948 Specifications

General IconGeneral
BrandSiemens
ModelCPU 948
CategoryController
LanguageEnglish

Related product manuals